Change Local Listening Port

Change Local Listening Port

Prerequisites

  • Office Manager Scope or Higher
  • Access to phones web gui 

Steps to take based on Brand

Polycom

Log into web gui and navigate to Settings -> SIP. Locate the option "Local SIP Port" and change this to any random port number above 1024. We recommend a number between 10000 and 65000. 



Click Save. The phone will now reboot and once rebooted will now register on the port that was set. 

Yealink

 Coming Soon

Grandstream

Log into web gui and navigate to Accounts -> Account X -> SIP Settings -> Basic Settings. Locate the option "Local SIP Port" and change this to any random port number above 1024. We recommend a number between 10000 and 65000. 



 

Htek

Coming Soon 

Cisco

Cisco SPA 112/122 ATA

Log into web gui and navigate to Voice -> Line1. Locate the option "SIP Port" under SIP Settings and change this to any random port number above 1024. We recommend a number between 10000 and 65000. 



Click Save. The phone will now reboot and once rebooted will now register on the port that was set. 

Cisco SPA 5xx Phone

Make sure you are in the Advanced settings under the Admin User



Then navigate to Voice -> Ext 1 . Locate the option "SIP Port" under SIP Settings and change this to any random port number above 1024. We recommend a number between 10000 and 65000. 



Click Save. The phone will now reboot and once rebooted will now register on the port that was set. 

    • Related Articles

    • Setup Manual or Softphone Device

      Unsupported phones and many unified communication softphones require manual configuration. The article below covers how to set up an account in the portal to be entered into the devices configuration.  All Manually setup devices need to have their ...
    • Grandstream P-Codes

      Grandstream P-Codes P-Code Retrieval One of the most common ways to generate a P-Code Template is to configure the phone using the WebUI and exporting the phones configuration, which can be found under Maintenance > Upgrade and provisioning. If you ...
    • Registering an Algo 8301 to a paging user extension

      Register Period (seconds)Prerequisites Active internet connection laptop/desktop connected to the network which the device is connected Portal configuration Create a User in extension 5800 Navigate to new user Navigate to the "Phones" tab Click ...
    • Yeastar S-Series - Add a SIP Trunk

      Tested on Yeastar S20 - Firmware – 30.11.0.28 Note - Caller ID must follow the NPANXX standard. The area code (NPA) must be a valid area code and the NXX must be a valid NXX. If the caller ID is not valid, then calls will not route properly and will ...
    • Unavailable Extensions

      Local Information and Emergency Numbers When using the Business Phone or Residential service the following actions are unavailable: N11 Number Dialed Action Notes 211 Allowed for Extension Dialing to extension 211 if assigned. It will not work for ...