Change Local Listening Port
Prerequisites
- Office Manager Scope or Higher
- Access to phones web gui
Steps to take based on Brand
Polycom
Log into web gui and navigate to Settings -> SIP. Locate the option "Local SIP Port" and change this to any random port number above 1024. We recommend a number between 10000 and 65000.
Click Save. The phone will now reboot and once rebooted will now register on the port that was set.
Yealink
Coming Soon
Grandstream
Log into web gui and navigate to Accounts -> Account X -> SIP Settings -> Basic Settings. Locate the option "Local SIP Port" and change this to any random port number above 1024. We recommend a number between 10000 and 65000.
Htek
Coming Soon
Cisco
Cisco SPA 112/122 ATA
Log into web gui and navigate to Voice -> Line1. Locate the option "SIP Port" under SIP Settings and change this to any random port number above 1024. We recommend a number between 10000 and 65000.
Click Save. The phone will now reboot and once rebooted will now register on the port that was set.
Cisco SPA 5xx Phone
Make sure you are in the Advanced settings under the Admin User
Then navigate to Voice -> Ext 1 . Locate the option "SIP Port" under SIP Settings and change this to any random port number above 1024. We recommend a number between 10000 and 65000.
Click Save. The phone will now reboot and once rebooted will now register on the port that was set.
Related Articles
Setup Manual or Softphone Device
Unsupported phones and many unified communication softphones require manual configuration. The article below covers how to set up an account in the portal to be entered into the devices configuration. All Manually setup devices need to have their ...
Registering an Algo 8301 to a paging user extension
Register Period (seconds)Prerequisites Active internet connection laptop/desktop connected to the network which the device is connected Portal configuration Create a User in extension 5800 Navigate to new user Navigate to the "Phones" tab Click ...
Yeastar S-Series - Add a SIP Trunk
Tested on Yeastar S20 - Firmware – 30.11.0.28 Note - Caller ID must follow the NPANXX standard. The area code (NPA) must be a valid area code and the NXX must be a valid NXX. If the caller ID is not valid, then calls will not route properly and will ...
Barge, Listen In, Or Whisper On Active Calls
This article discusses the Whisper, Listen, and Barge features within the Portal. Prerequisites Call Center Supervisor scope A registered device for your user Listen In To A Call From the Call Center tab, click the speaker icon next to the agent you ...
Thompson Speedtouch ST-585
Current Status Untested Suggestions Untested Comments The internal SIP service needs to be disabled. You will need to use a telnet (port 23) client to connect to the ip address of this router using putty or another telnet client. The username and ...